价格 | 1.00元 |
---|---|
品牌 | point light |
区域 | 全国 |
来源 | 鹏鑫(泉州)贸易有限公司 |
详情描述:
POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION PL10760-x-D4 One head operating & one head standby. Upon failure of the operating head, power is transferred to the standby head and to alarm contacts. The alarm contacts are isolated (voltage free) normally open and normally closed. PL10760-x-D4.2 Both heads operating. Upon failure of one head, the alarm contacts are activated. The alarm contacts are isolated “dry” (voltage free) normally open and normally closed. PL10760-x-D7 Both heads operating & flashing simultaneously. No alarm function. PL10760-x-D8 One operating head that is flashing and one standby head. Upon failure of the operating head, power is transferred to the standby head and it flashes. No alarm function. PL10760-X-D10 One operating head is flashing and one standby head. Upon failure of the operating head, the standby head activates & flashes and a failure alarm line is activated powered by the POL’s normal line voltage. PL10760-x-D14 Both heads operating & flashing simultaneously. Upon failure of the first head, the alarm contacts are activated. The alarm contacts are isolated “dry” (voltage free) normally open and normally closed. PL10760-x-D15 Both heads operating & flashing simultaneously. Upon failure of the first head, the alarm line is activated powered by the POL’s normal line voltage. CONTROL & MONITORING OPTIONS ADD THE SELECTED UNIT TO EACH POL LIGHT * * The PL10760-xx Control Unit is Class I, Division 2 and must be installed within 3-ft (1-meter) of its associated POL-EX obstruction light. Proper installation and sealing in accordance with all applicable standards is the responsibility of the installer. See page 4 for enclosure details. POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION POL EX SPECIFICATIONS The red LED lighted (specify: voltage) aviation obstruction light shall be tested and certified FAA L-810 (ICAO low intensity Type B). The obstruction light shall operate properly at 50 or 60 Hz at an input voltage supply of 120V (93V to 144V) or 220V units (176V to 250V). Within the preceding ranges, the output to the LED board shall be a controlled, stabilized constant current. The obstruction lights shall be listed and labeled for use in hazardous locations: Class I, Division 2, Groups A, B, C, D & T5 and Class 1, Zone 2, Groups IIA, IIB H, IIC with a temperature rating of T5 at max 55-deg C per UL 844 & CSA C22.2 No. 137-M1981. The AC obstruction lights shall be listed Suitable for Use in Wet Locations to UL1598A Marine Vessels (for AC), UL1598 2nd Edition Luminaries; CSA C22.2 No. 250.0-08, 2nd Edition; UL50 11th Edition Standard for Enclosures for Electrical Equipment and CSA C22.2 No. 94-M91 Special Purpose Enclosures for use at -40 deg C to 55 deg C and sealed to IP66 ingress protection. The unit shall have passed the FAA certification tests: the constant high temperature test to 130 deg F ( 55 deg C) and the constant low temperature test to -67 deg F (-55 deg C) conducted in accordance with US MILSTD-810F, Method 501.4, Procedure II; the wind-blown rain test conducted in accordance with US MIL-STD-810E, Method 506.3, Procedure I; and the humidity test shall be in accordance with US MIL-STD-810E, Method 507.3, Procedure I. The complete test regime shall exceed the requirements of NEMA 4X and IP 66. The light head shall be marine treated for corrosion resistance certified by the manufacturer to comply with the US Military Standard Salt Fog Test conducted per MIL-STD-810F, Method 509.4, Procedure I, paragraph 4.5.2. The Marine Treatment finish shall be bonded to the metal. The fixture shall be treated for marine conditions by cleaning per US Department of Defense TT-C-490 method III, pretreated with chrome-free aluminum conversion coating per US MIL-C-5541 type II, epoxy powder base coat primer and glossy polyester powder coat finish. Powder coating per US Department of Defense MIL-PRF- 24712A type VI and oven cured. The lens shall be strong soda lime glass and shall be smooth and rounded to reduce the adhesion of dirt, ice and snow. The glass shall be clear to maximize light transmissivity. The red emitting LEDs shall meet the chromaticity requirements of US MIL-C-25050. The high output LED’s be the latest technology providing uniform light output in 360 degrees horizontal. The LED average life shall exceed 100,000 hours. The LEDs shall be soldered in a factory set position to insure consistent light output. Wire mounted raised LEDs that can be bent out of position shall be unacceptable and cause for rejection. The LED board shall be treated with a protective dielectric conformal coating for protection from moisture and corrosion. The power supply board shall include short circuit and open circuit protection and the unit shall be protected from line surges by metal oxide varistors (MOVs). There shall be a clear design element for the dissipation of LED heat to insure the LEDs do not fail prematurely. The red LED aviation obstruction light shall be POINTSPEC Series POL-21005-EX manufactured by Point Lighting Corporation. Important Note: Alarm and other control options must be selected at time of initial order by adding the proper PL10760 unit. The POL-EX LED light can only be monitored by 3rd party systems or controllers by selecting a POL-EX with a PL10760 monitoring unit. POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION PL10760 ALARM & MONITORING UNIT The Alarm & Monitoring Unit must be installed in accordance with all applicable local electrical codes within 3-ft (1-meter) of the POL EX light fixture. The PL10760 monitors the LEDs and translates the signal into a form usable by a POC controller or other alarm scheme. Two listed enclosures are used depending on the functions required. The following are the standard applications. Enclosure A is used for the following versions: S2 S4 DT D2 D4 D7 Enclosure B is used for the following versions: D2.2 D4.2 D8 D10 D14 D15 PL10760 ENCLOSURE A Manufacturer: Crouse-Hinds File: QBCR.E10518 Class I, Divisions 1 & 2, Groups A B C D PL10760 ENCLOSURE B Manufacturer: Akron File: E139669 Class I, Divisions 1 & 2, Groups B C D NEMA 4X, 7, 9 POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION POWER CONSUMPTION PER POL EX LIGHT HEAD Note: For option –NC, add 1.0 watts (1.1 VA) REPLACEMENT PARTS Note: Single POLs and the fixture heads of double POLs are permanently sealed. In the event of failure, the fixture must be returned to the factory for evaluation and repair. Note: Failure caused by surge normally requires fixture replacement Code Type Voltage Frequency Watts* mA VA* -1F FAA & ICAO A 120 AC 50/60 Hz 1.5 25 2.9 -2F FAA & ICAO A 220 AC 50/60 Hz 2.1 25 5.5 -3F FAA & ICAO A 12 DC --- 1.2 96 1.2 -4F FAA & ICAO A 24 DC --- 1.5 62 1.5 -5F FAA & ICAO A 48 DC --- 1.2 25 1.2 -6F FAA & ICAO A 277 AC 50/60 Hz 1.9 24 5.9 -1B ICAO B & TRAN CAN 120 AC 50/60 Hz 6.9 63 7.6 -2B ICAO B & TRAN CAN 220 AC 50/60 Hz 6.9 34 7.4 -3B ICAO B & TRAN CAN 12 DC --- 4.3 470 4.3 -4B ICAO B & TRAN CAN 24 DC --- 4.3 230 4.3 -5B ICAO B & TRAN CAN 48 DC --- 5.0 104 5.0 -6B ICAO B & TRAN CAN 277 AC 50/60 Hz 6.9 28 7.9 WEIGHT, DIMENSIONS & SHIPPING DATA inches (mm) Multi-Pack Carton Weight Height Width Depth Qty Weight Dim (inches) POINTSPEC Single: 3.5 lbs 1.6 kg 8.6 (210) 6.0 (152) 5.0 (127) 12 47 lbs 21.3 kg 22 x 15 x 17 POINTSPEC Double: 11.8 lbs 5.4 kg 13.3 (337) 14.9 (378) 5.0 (127) 2 27 lbs 12.3 kg 19 x 19 x 19 Wind Loading: Effective Projected Area (EPA) for POINTSPEC Double 0.69 square feet P O I N T L I G H T I N G C O R P O R A T I O N Mail: P.O. Box 686, Simsbury, CT 06070 Plant: 61-65 W. Dudley Town Rd, Bloomfield, CT Tel 01 860.243.0600 USA Fax 01 860.243.0665 email: Info@PointLighting.com website: www.PointLighting.com *Power consumption for AC units includes the effect of the unit’s power factor which accounts for the difference between watts and volt-amperes. Measurements were made at the nominal AC voltages. The operating range for 120v units: 93 - 144v; for 220v units: 176 - 250v; for 277v units: 263 -291v.EMKOESM-9920.5.20.0.1/01.02/0.0.0.0温控器 SuS2.pap.300插头 DEUFRAPD210 1000 Ohm in AS50 RP22/6038电位计 ACLATHAN140409滚轮 KOSTYRKA5350.040.100轴套 stiefelmayer450182测量工具 ROSAF.932094 0012839/2012 SL. BEARING MG35 SL Q3 P2滑块 巴鲁夫balluffBSW 819-493-12K2 SCHMIDT-KUPPLUNG GmbHSemiflex F 70.66 φ16 φ16 alte Bez. NFB 4.7/2 A2φ16N A2φ16N联轴器 Mubea Fahrwerksfedern GmbHGO292/0-e32工具钳 ELESA GANTERGN 552-31-M22X1,5-A-2透气塞 巴鲁夫balluffBSW 819-494-X64-WA-06L3 LOHSEA037145修理包 Weigel MessgeraetTYPE 24.03.09 DAS10-40PR S-NR 1041133-68功率放大器 巴鲁夫balluffBIC 1I0-N2A02-M18TI-BPX03-050 KnickP42001D3隔离放大器 ARP GmbHArt.-Nr:226608网卡 Minco GmbHTT355TJ1YW自动控制器 SAW BLANK STAHL GmbHLDFG-DA 34304-40-LF-111滑块 C. Gerhardt GmbH & Co. KGEV16加热板 RINCK ELECTRONIC GMBHLF8光照传感器 j-schneiderAKKUTEC 2420-0 3PH, NBPA0313G01002电源模块 HuebnerHOG10D1024I S/N: 2367920编码器 HANS HENNIG GmbHFD-KG冷却夹套 Grafix GmbHArtikel Nr. 3620019过滤器
联系人 | 吴工 |
---|